{"id":599,"date":"2020-04-13T15:28:10","date_gmt":"2020-04-13T18:28:10","guid":{"rendered":"http:\/\/www.bioimpec.com\/?post_type=product&#038;p=599"},"modified":"2026-01-12T14:07:46","modified_gmt":"2026-01-12T17:07:46","slug":"nutri-o2","status":"publish","type":"product","link":"https:\/\/www.bioimpec.com\/es\/producto\/nutri-o2\/","title":{"rendered":"Nutri+ O2"},"content":{"rendered":"<p><strong>NUTRI+ O2<\/strong> es una formulaci\u00f3n que contiene micronutrientes esenciales para el crecimiento y el \u00a0metabolismo celular de los microorganismos presentes en sistemas de tratamiento de aguas residuales aer\u00f3bicos.<\/p>\n<p><strong>Usos: <\/strong>estimula el crecimiento de diversos g\u00e9neros microbianos incrementando la variedad y actividad de la biomasa, \u00a0permitiendo responder en forma r\u00e1pida y eficiente a los cambios que est\u00e1 sometida (sobrecargas y shocks t\u00f3xicos).<\/p>\n<p><strong>Beneficios: <\/strong>permite mejorar significativamente el funcionamiento de las plantas biol\u00f3gicas tanto\u00a0 en filtros percoladores, lodos Activados o lagunas aireadas.<\/p>\n<ul>\n<li>Incrementa la remoci\u00f3n de DBO y DQO.<\/li>\n<li>Reduce la turbiedad del vuelco.<\/li>\n<li>Evita la formaci\u00f3n de microorganismos filamentosos.<\/li>\n<li>Reduce las purgas requeridas del sistema.<\/li>\n<li>Mejora la decantabilidad del lodo.<\/li>\n<li>Acelera el comienzo bi\u00f3logico de sistemas<br \/>\nnuevos y ayuda en el caso de sistemas<br \/>\nque han sufrido problemas.<\/li>\n<li>Operaci\u00f3n mejorada en climas fr\u00edos<\/li>\n<li>Aumenta la estabilidad del sistema frente a picos de carga<\/li>\n<li>Funciona para Lodos Activados, Lagunas y otros reactores aer\u00f3bicos<\/li>\n<\/ul>\n<p>&nbsp;<\/p>\n<p><strong>Dosis: <a href=\"https:\/\/www.bioimpec.com\/287ae-contact\/\">SOLICITAR FICHA T\u00c9CNICA<\/a><\/strong><\/p>\n<p>Aplicaci\u00f3n: Se puede realizar directamente en el reactor aer\u00f3bico, laguna o en el retorno de lodos.<\/p>\n<p><strong>Presentaci\u00f3n: <\/strong>Producto en polvo en balde de 20 kg.<\/p>\n<p>&nbsp;<\/p>\n<p>ENGLISH SPECS &#8211; NUTRI+ O2 for WWTP<\/p>\n<p class=\"aWBg0w aZskFA u16U_g mKhvSg\"><b>Product Purpose:<\/b><br \/>\nNutri+ O2 is designed to support and accelerate the biological treatment of wastewater by providing essential nutrients and improving oxygen availability for microorganisms responsible for decomposition.<\/p>\n<p class=\"aWBg0w aZskFA u16U_g mKhvSg\"><b>Key Functions:<\/b><\/p>\n<div class=\"aWBg0w aZskFA u16U_g mKhvSg\">\n<ul class=\"_8k16_w\">\n<li><b>Nutrient Supplementation:<\/b> Supplies nitrogen, phosphorus, and trace elements that microorganisms need for growth and metabolism.<\/li>\n<li><b>Oxygen Enhancement:<\/b> Improves dissolved oxygen levels, promoting aerobic bacterial activity and reducing odors.<\/li>\n<li><b>Process Stabilization:<\/b> Helps maintain consistent biological performance, especially during shock loads or variable influent conditions.<\/li>\n<li><b>Sludge Reduction:<\/b> Enhances biodegradation, leading to lower sludge production and easier handling.<\/li>\n<\/ul>\n<\/div>\n<p class=\"aWBg0w aZskFA u16U_g mKhvSg\"><b>Applications:<\/b><\/p>\n<div class=\"aWBg0w aZskFA u16U_g mKhvSg\">\n<ul class=\"_8k16_w\">\n<li>Municipal wastewater treatment plants<\/li>\n<li>Industrial effluent treatment (food processing, paper mills, chemical industries)<\/li>\n<li>Septic systems and lagoons<\/li>\n<li>Odor control in anaerobic zones<\/li>\n<\/ul>\n<\/div>\n<p class=\"aWBg0w aZskFA u16U_g mKhvSg\"><b>Typical Benefits:<\/b><\/p>\n<div class=\"aWBg0w aZskFA u16U_g mKhvSg\">\n<ul class=\"_8k16_w\">\n<li>Faster organic load reduction (BOD\/COD)<\/li>\n<li>Improved effluent quality<\/li>\n<li>Reduced chemical oxygen demand<\/li>\n<li>Lower operational costs due to improved biological efficiency<\/li>\n<\/ul>\n<\/div>\n<p>&nbsp;<\/p>\n<p>&nbsp;<\/p>\n","protected":false},"excerpt":{"rendered":"<p><strong>PLANTAS CON BAJA CALIDAD DE BIOMASA (MALA SEDIMENTABILIDAD): <\/strong><\/p>\n<p>Micronutrientes esenciales para la POTENCIACI\u00d3N de microorganismos presentes en sistemas de tratamiento de aguas residuales AER\u00d3BICOS.<\/p>\n","protected":false},"featured_media":2142,"template":"","meta":{"neve_meta_sidebar":"right","neve_meta_container":"","neve_meta_enable_content_width":"off","neve_meta_content_width":70,"neve_meta_title_alignment":"","neve_meta_author_avatar":"","neve_post_elements_order":"","neve_meta_disable_header":"","neve_meta_disable_footer":"","neve_meta_disable_title":""},"product_brand":[],"product_cat":[33],"product_tag":[],"class_list":["post-599","product","type-product","status-publish","has-post-thumbnail","product_cat-aguas-residuales","first","instock","shipping-taxable","product-type-simple"],"_links":{"self":[{"href":"https:\/\/www.bioimpec.com\/es\/wp-json\/wp\/v2\/product\/599","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.bioimpec.com\/es\/wp-json\/wp\/v2\/product"}],"about":[{"href":"https:\/\/www.bioimpec.com\/es\/wp-json\/wp\/v2\/types\/product"}],"version-history":[{"count":9,"href":"https:\/\/www.bioimpec.com\/es\/wp-json\/wp\/v2\/product\/599\/revisions"}],"predecessor-version":[{"id":10647,"href":"https:\/\/www.bioimpec.com\/es\/wp-json\/wp\/v2\/product\/599\/revisions\/10647"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/www.bioimpec.com\/es\/wp-json\/wp\/v2\/media\/2142"}],"wp:attachment":[{"href":"https:\/\/www.bioimpec.com\/es\/wp-json\/wp\/v2\/media?parent=599"}],"wp:term":[{"taxonomy":"product_brand","embeddable":true,"href":"https:\/\/www.bioimpec.com\/es\/wp-json\/wp\/v2\/product_brand?post=599"},{"taxonomy":"product_cat","embeddable":true,"href":"https:\/\/www.bioimpec.com\/es\/wp-json\/wp\/v2\/product_cat?post=599"},{"taxonomy":"product_tag","embeddable":true,"href":"https:\/\/www.bioimpec.com\/es\/wp-json\/wp\/v2\/product_tag?post=599"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}